Trikdis FLEXi Keypad SK-LCD button – Brief User Guide

Trikdis FLEXi Keypad SK-LCD button – Brief User Guide
Keypad Overview

Function Overview

  1. Date
  2. Time
  3. Area Status Indication
  4. Area Control Buttons
  5. Menu Button
Arming / Disarming the Alarm System

Alarm System (Away) ARMING

  1. Make sure no zones are violated.
  2. Press the [lock] button.
  3. Enter your user code.
  4. Select the area.
  5. Press the [check mark] button.
  6. Leave the area within the exit delay time.

When the system is armed, the lock with 1 label icon appears on the display.

Alarm System DISARMING

  1. Enter your user code.
  2. Select the area.
  3. Press the [check mark] button.

When the system is disarmed, the open lock with 4 label icon appears on the display.

NIGHT / SLEEP Mode

The building's perimeter is secured, free movement inside is allowed. Alarms upon door/window opening.

  1. Press the [night arming] button.
  2. Enter your user code.
  3. Select the area.
  4. Press the [check mark] button.
  5. NIGHT arming activates immediately.

The moon behind cloud with 3 label icon appears on the display when NIGHT arming is active.

STAY Mode

There is an entry delay. Free movement inside is allowed.

  1. Press the [person in a house] button.
  2. Enter your user code.
  3. Select the area.
  4. Press the [check mark] button.
  5. STAY arming activates immediately.

The person in house with 2 label icon appears on the display when STAY arming is active.

To change the area status, simply enter the user code and select the desired area. To clear entered commands, press the [back] button.

Creating, Modifying, Deleting Codes

Adding a new code / Modifying an existing one:

  1. Press the [menu], then the [0] button.
  2. Enter the master code (default: 1234).
  3. Enter the two-digit serial number of the user (e.g., 02).
  4. Enter the new code twice.
  5. Select the areas assigned to the user.
  6. Press the [check mark] button.

To exit, press the [back] button again.

Note

  • Master code serial number: [01]
  • Codes consist of 4 digits.

Deleting a user code:

  1. Press the [menu], then the [0] button.
  2. Enter the master code.
  3. Enter the two-digit serial number of the user (e.g., 02).
  4. Press the [night arming] button. (A confirmation sound will be heard.)
  5. Press the [check mark] button.

To exit, press the [back] button again.

Zone Bypass (BYPASS)

Activating Bypass:

  1. Press the [menu], then the [6] button.
  2. Enter your user code.
  3. Enter the two-digit serial number(s) of the zone(s). You can enter multiple, e.g., 05 then 11.
  4. Press the [check mark] button. (The crossed out open door icon appears on the display if there is a bypassed zone.)

Deactivating Bypass:

Repeat the activation steps.

Emergency Buttons, Fire Detector Reset

Sending an Emergency Signal:

  • Police – press button [1] for 3 seconds
  • Medical Aid – press button [4] for 3 seconds
  • Fire Department – press button [7] for 3 seconds

Note: This only works with an active remote monitoring subscription.

Resetting Fire (Smoke) Detectors:

  • Press the [back] button for 3 seconds.

Note: Fire and/or smoke detectors do not reset automatically after an alarm. They must be reset manually.

Light and Sound Settings

Button Brightness

  1. Press the [menu], then buttons [5] and [3].
  2. Adjust the brightness with buttons [2] / [8].
  3. To save [check mark], to exit [back].

LCD Display Brightness

  1. Press the [menu], then buttons [5] and [2].
  2. Adjust the brightness with buttons [2] / [8].
  3. To save [check mark], to exit [back].

Keypad Volume

  1. Press the [menu], then buttons [5] and [1].
  2. Adjust the volume with buttons [2] / [8].
  3. To save [check mark], to exit [back].

Disabling Standby Light

This setting controls whether the keypad backlight illuminates even when the device enters standby mode (i.e., has not been pressed for a while).

  1. Press the [menu], then buttons [5] and [4].
  2. By pressing button [1], you can set the backlight to illuminate in standby mode, while with button [2], you can set it to turn off.
  3. To save [check mark], to exit [back].
Meaning of Symbols
Control panel not connected
Control panel not connected
Partition 1 armed
Area 1 armed
Partition 4 disarmed
Area 4 disarmed
Partition 2 home mode
Area 2 stay mode
Partition 3 sleep mode
Area 3 sleep mode
MENU button
MENU button
ENTER function button
ENTER function button
Partition
Area
Alarm
Alarm
Fire
Fire
User code
User code
User
User
Entry/Exit
Entry/Exit
Open zone
Open zone
Bypass
Bypass
Memory
Memory
Trouble
Trouble
System trouble list
System trouble list
AC power trouble
AC power trouble
Battery trouble
Battery trouble
AUX overcurrent
AUX overcurrent
Time not set
Time not set
Bell overcurrent
Bell overcurrent
Bell missing
Bell missing
Fire loop trouble
Fire loop trouble
Network trouble list
Network trouble list
CMS 1 (2) trouble
1. Central Monitoring Station (CMS) trouble
Cloud connection trouble
Cloud connection trouble
SIM card trouble
SIM card trouble
SIM card password trouble
SIM card password trouble
SIM card network trouble
SIM card network trouble
WiFi trouble
WiFi trouble
RS485 interface trouble
RS485 interface trouble
SIM card 2 trouble
SIM card 2 trouble
LAN trouble
LAN trouble
Wireless low battery
Wireless low battery
Power trouble
Power trouble
Bell trouble
Bell trouble
Tamper trouble
Tamper trouble
Antimasking trouble
Antimasking trouble
Wireless trouble
Wireless trouble
Expander module trouble
Expander module trouble
Settings
Settings
Volume
Volume
LCD brightness
LCD brightness
Keypad brightness
Keypad brightness
Standby light O-On / I-Off
Standby light O-On / I-Off
Info
Info

The "SK-LED button" keypad manages 64 zones and 8 areas. Areas can be assigned to individual keypads, in which case the keypad will only display the status of the assigned areas. This function is available from alarm control panel FW:SP3_xxx4_0121 version.