Features

Communication:

  • In line of sight, the range can reach up to 5000 meters.
  • Up to 8 IO-LoRa wireless expanders can be connected to the FLEXi SP3 control panel.

Inputs and outputs:

  • 1-Wire bus: for connecting temperature sensors (up to 4 pcs) or electronic key ("iButton") readers.
  • 1 input, selectable type: NC, NO.
  • 1 output (relay).

Connection:

  • The IO-8-LoRa wireless expander connects to the FLEXi SP3 control panel via the RF-LoRa transceiver.
trikdis io-lora wireless expander module io-lora 26

Building a wireless or hybrid system?

The Trikdis RF-LORA wireless transceiver is the central element of the Trikdis wireless family. By connecting an RF-LORA to the Trikdis FLEXi SP3 control panel, you can build a wireless or hybrid (= mixed: wired and wireless) alarm system. These wireless devices can be sensors, sirens, panic buttons, or remote expansion modules with inputs (zones) or controllable outputs (PGMs), anything that might be needed for a smart alarm system.

Compatible devices with RF-LORA

  • IO8-LORA - wireless expander with 8 contact (all contact can be chosen as input or output)
  • IO-LORA - wireless expander with built in relay (mostly used for gates, doors, barriers, garage doors)
  • PB-LORA - wireless panic button (use up to 250 panic buttons in one system )
  • M4-MAG - wireless magnetic door contact
  • M4-PIR - wireless Indoor PIR
  • M4-SMK - wireless smoke detector
  • M4-SMK-H - wireless smoke and heat detector
  • M4-SIREN - wireless outdoor siren
  • M4-SIREN-IN - wireless indoor siren
trikdis io-lora wireless expander module io-lora 27

About LoRa technology in general

LoRa devices are revolutionizing the Internet of Things (IoT) by enabling data communication over longer distances than usual while consuming very little energy. LoRa is ideal for applications that transmit small amounts of data at low bit rates, and the data can be transmitted over longer distances than WiFi, Bluetooth, or ZigBee. It is also an ideal choice in places where the mobile network is too expensive and Wi-Fi coverage is not available.

LoRa is already widely used in street lighting, parking, buildings, smart metering and fleet management. The LoRa solution provides an intelligent sensor and control security system that allows connected devices to be easily controlled and receive messages in order to make intelligent decisions about the services offered.

Trikdis chose LoRa communication technology because it allows messages to be transmitted over much greater distances than traditional wireless networks. In many cases, this can significantly reduce the cost of building a complex smart security system due to infrastructure investments, battery replacement and overall operational costs. Such a solution allows devices or sensors to be connected at a distance of up to 1-5 kilometers, sometimes even further. This technology also passes through obstacles more easily than traditional radio communication, so it confidently transmits the signal over thick concrete walls or even on the ground, naturally with some loss of distance.

Advantages of LoRa technology:

  • Low cost installation and operation
  • Flexible deployment model
  • End-to-end security
  • Low power consumption, longer battery life
  • High coverage for IoT where speed and latency are not critical factors
  • Long range that penetrates obstacles more easily

Communication

Communication with the other device
Radio
Connection with alarm control panel
RS485
Transmission Protocol, Encryption
Encrypted
RS485
Yes

Compatible devices

Supported Modules
RF-LORA
1 Wire data bus
Yes, max 30m wire length
Supported Temperature Sensors
max. 4 x (Dallas DS18S20, DS18B20 )
Supported Electric Key (iButton) Readers
Maxim® / Dallas® DS1990A

Inputs

Inputs
1
Input types
NC, NO

Outputs

Output (dedicated)
1 relay, 250 V AC, 4 A
Control
Mobile app, browser, SMS, phone call

Technical data

Operating environment
-20°C - +50°C, relative air humidity up to 80% at +20°C
Power supply
10-26 V DC
Current consumption (nominal)
50 mA
Current consumption (max)
120 mA
Size
62 x 77 x 25 mm
Weight
80 g
PGM output
100 mA
Modulation Type
LoRa
Frequency Band
867-869 MHz
Range in open space
5000m

Related Products

Tags:

Frequently asked questions

A Security panel or Control panel is the primary controller and supervisor of a security system.

A Security panel or Control panel is the primary controller and supervisor of a security system. It is a computer that arms and disarms the security systems, communicates with each installed component, like sensors and sounds the alarm when a security zone is breached, and optionally communicates with an alarm monitoring company.

Hopefully not. Basically, the phone should be protected from any access by using a password or pattern or fingerprint. In addition, you can use password request when you start the Protegus application and also when you want remotely control something.

Hopefully not. Basically, the phone should be protected from any access by using a password or pattern or fingerprint. In addition, you can use password request when you start the Protegus application and also when you want remotely control something. At least one of them should be active, but two or three of these steps will make it pretty difficult for anyone to access your alarm system!

Protegus 2 is the 2nd generation of Trikdis's cloud app: control your alarm system from your phone and get instant notifications. We recommend it for every current internet-connected Trikdis device. The user app is free; the paid, usage- (customer-) based tier is for monitoring stations, installers and companies.

Yes, using the TrikdisConfig programming software (via USB or remotely). The latest firmware is recommended for the best compatibility and security.

Yes: Protegus 2 can be tried on a live demo system, without installation or purchase — from a browser and from the mobile app too. This lets you see in advance what arming, notifications, and system status look like on a working alarm system.

There is no standalone Trikdis communicator that communicates exclusively over Wi-Fi, but the SIM-card communicators can be extended with the W485 Wi-Fi expansion module. There is also a purely Wi-Fi version, as well as a Wi-Fi + SIM 4G version, of the FLEXi SP3 alarm panel.

Currently the FLEXi SP3, the CG17, and the GV17 support SMS forwarding; this feature is not yet available on the other devices.

Protegus 2 typically retains the event list for up to two months; with a large volume of events, this period may shorten to as little as one month.

The AUX power output of the Paradox SP4000 alarm panel has limited load capacity. In certain cases — whether using a dedicated or a universal TRIKDIS communicator — the communicator's current draw can place too much load on the AUX output. As a result, the communicator may become unstable, restart, or fail to operate correctly.

Experience shows that the problem is usually solved by powering the TRIKDIS communicator directly from the alarm panel's battery terminals (+/-) instead of from the AUX output. This provides a stable power supply and eliminates the restart or operational issues.

Note: Before changing the wiring, always check that the system complies with the manufacturer's specifications and that the total load on the power supply does not exceed the permitted value.