RF-LORA
Expansion module
  • Trikdis IO8-LORA wireless expander module

Trikdis IO8-LORA wireless expander module

  • €58.90 Ex Tax: €47.89


With Trikdis LoRa wireless expansion devices, it is possible to create multiple remote connection points for the Trikdis FLEXi SP3 alarm system control panel.

One of its members is the IO8-LoRa expansion module. There are 8 contacts on the module, which can optionally be input (e.g. alarm zone) or controllable output (gate opening, pump start). A total of up to 8 controllable devices or zones can be doubled, and 16 alarm zones can be connected to it via wire.

Features

Communication:

  • Line-of-sight wireless range up to 5000 m.
  • Up to 8 iO8-LoRa wireless expanders can be connected to the “FLEXi” SP3 control panel.

Inputs and outputs:

  • 8 I/O terminals, each one can be set as an input (IN) or output (OUT).
  • Input (IN) types: ATZ, EOL, NC, NO.
  • Different value of resistors can be used in EOL and ATZ type circuits.

Connection:

  • The iO-8-LoRa wireless expander is connected to the “FLEXi” SP3 control panel via the RF-LoRa transceiver.

LoRa technology logo

About LoRa technology in general

LoRa devices are revolutionizing the Internet of Things (IoT) by enabling data communication over longer distances than usual while consuming very little energy. LoRa is ideal for applications that transmit small amounts of data at low bit rates, and the data can be transmitted over longer distances than WiFi, Bluetooth, or ZigBee. It is also an ideal choice in places where the mobile network is too expensive and Wi-Fi coverage is not available.

LoRa is already widely used in street lighting, parking, buildings, smart metering and fleet management. The LoRa solution provides an intelligent sensor and control security system that allows connected devices to be easily controlled and receive messages in order to make intelligent decisions about the services offered.

Trikdis chose LoRa communication technology because it allows messages to be transmitted over much greater distances than traditional wireless networks. In many cases, this can significantly reduce the cost of building a complex smart security system due to infrastructure investments, battery replacement and overall operational costs. Such a solution allows devices or sensors to be connected at a distance of up to 1-5 kilometers, sometimes even further. This technology also passes through obstacles more easily than traditional radio communication, so it confidently transmits the signal over thick concrete walls or even on the ground, naturally with some loss of distance.

Advantages of LoRa technology:

  • Low cost installation and operation
  • Flexible deployment model
  • End-to-end security
  • Low power consumption, longer battery life
  • High coverage for IoT where speed and latency are not critical factors
  • Long range that penetrates obstacles more easily

Communication

Communication with the other device
Radio
Connection with alarm control panel
RS485
Transmission Protocol, Encryption
Encrypted
RS485
Yes

Compatible devices

Supported Modules

Contacts (inputs and outputs)

Selectable-function contact (output or input)
8
Input types
NC, NO, EOL, EOL_T, 3EOL, ATZ, ATZ_T
Loop resistance
2.2kΩ
Control
Mobile app, browser, SMS, phone call

Technical data

Operating environment
-20°C - +50°C, relative air humidity up to 80% at +20°C
Power supply
10-26 V DC
Current consumption (nominal)
50 mA
Current consumption (max)
120 mA
Size
65 x 90 x 12 mm
Weight
80 g
PGM output
100 mA
Modulation Type
LoRa
Frequency Band
867-869 MHz
Range in open space
5000m

Write a review

Note: HTML is not translated!
    Bad           Good

Related Products

Related Articles

Tags

Frequently asked questions

Yes. Both expanders have 8 I/O terminals that can each be set as an input or an output; as inputs, the ATZ, EOL, NC and NO types are available. With ATZ zone doubling one expander provides 16 alarm zones instead of 8. Several resistor values can be used in ATZ and EOL circuits, so the existing wiring and resistors can be kept.

Yes, both expanders support ATZ zone doubling.

The IO8-LORA (wireless, via the RF-LORA transceiver) and the IO8 (wired, over RS485) each have 8 I/O terminals, and every terminal can be set individually as an input (IN) or an output (OUT).

As inputs, the following types are available: ATZ, EOL, NC, NO. With ATZ zone doubling one expander provides 16 alarm zones instead of 8.

Several resistor values can be used in ATZ and EOL circuits, so the wiring and the resistors of an existing system (Paradox, DSC, BOSCH, Crow) can be kept — when replacing a panel the detectors do not have to be rewired.

The input type and the resistor values are set in the alarm panel, using the TrikdisConfig programming software. The number of zones is of course limited by the total zone capacity of the panel.

All questions

🇪🇺Official EU distributiondirect from the factory
🛠️Expert supportfor installers too
✓Factory warrantyon every product
🚚Fast deliveryfrom stock