• Trikdis ME301M magnetic antenna with 2,5m wire

Trikdis ME301M magnetic antenna with 2,5m wire

  • €21.99 Ex Tax: €17.88


ME301M is a magnetic GSM antenna with a 2.5m wire, which allows the user to place the transceiver further away from the shaded area, thus improving the reliability of communication.

Technical data

Frequency Range
870-960MHz / 1710-1990MHz
Operating environment
- 40 --C - +85 ºC
VSWR
≥1.6
Gain
3.5dBi
Impedance
50Ω
Polarization
vertical
Connector
SMA / male
Wire
2.5m
Color
Black
Size
Ø 30 x 73mm
Weight
100g

Write a review

Note: HTML is not translated!
    Bad           Good

Related Products

Tags

Frequently asked questions

4G (LTE) is faster and more future-proof, since 2G networks are being phased out. For new installations, 4G is recommended; 2G is cheaper and can be an advantage where 4G coverage is weak. Many models (FLEXi SP3, G16, CG17, G17F) are available in both versions.

Traditionally via telephone line (TIP/RING) — a universal solution that lets devices communicate regardless of brand. Trikdis's own development means that panels on the supported list (and only those) can also be connected directly and digitally via serial port or data cable — as far as we know, no one else offers this, backed by 10-15 years of development.

Protegus 2 is the 2nd generation of Trikdis's cloud app: control your alarm system from your phone and get instant notifications. We recommend it for every current internet-connected Trikdis device. The user app is free; the paid, usage- (customer-) based tier is for monitoring stations, installers and companies.

Yes, using the TrikdisConfig programming software (via USB or remotely). The latest firmware is recommended for the best compatibility and security.

Yes: Protegus 2 can be tried on a live demo system, without installation or purchase — from a browser and from the mobile app too. This lets you see in advance what arming, notifications, and system status look like on a working alarm system.

There is no standalone Trikdis communicator that communicates exclusively over Wi-Fi, but the SIM-card communicators can be extended with the W485 Wi-Fi expansion module. There is also a purely Wi-Fi version, as well as a Wi-Fi + SIM 4G version, of the FLEXi SP3 alarm panel.

Currently the FLEXi SP3, the CG17, and the GV17 support SMS forwarding; this feature is not yet available on the other devices.

Protegus 2 typically retains the event list for up to two months; with a large volume of events, this period may shorten to as little as one month.

The AUX power output of the Paradox SP4000 alarm panel has limited load capacity. In certain cases — whether using a dedicated or a universal TRIKDIS communicator — the communicator's current draw can place too much load on the AUX output. As a result, the communicator may become unstable, restart, or fail to operate correctly.

Experience shows that the problem is usually solved by powering the TRIKDIS communicator directly from the alarm panel's battery terminals (+/-) instead of from the AUX output. This provides a stable power supply and eliminates the restart or operational issues.

Note: Before changing the wiring, always check that the system complies with the manufacturer's specifications and that the total load on the power supply does not exceed the permitted value.

All questions

Related Articles

G16 – Direct Control for DSC PowerSeries Alarm Control Panels

G16 – Direct Control for DSC PowerSeries Alarm Control Panels

  • 26/06/2018

The G16 communicator supports direct bidirectional control of DSC PowerSeries alarm control panels.

Read More
GV17 GATOR gate controller – installation and programming manual

GV17 GATOR gate controller – installation and programming manual

  • 06/11/2026

Installation and programming manual for the Trikdis GV17 GATOR gate controller: wiring, SIM and setup in TrikdisConfig, users and permissions, control by phone call, SMS and from the Protegus 2 app.

Read More
GET communicator – installer and user manual

GET communicator – installer and user manual

  • 05/11/2026

Installer and user manual for the Trikdis GET Ethernet + 4G communicator: connection to the alarm control panel, LAN and SIM setup in TrikdisConfig, reporting to the monitoring station, the Protegus 2 app.

Read More
CG17 alarm panel – installation and programming manual

CG17 alarm panel – installation and programming manual

  • 30/10/2026

Installation and programming manual for the Trikdis CG17 cellular alarm panel: wiring and SIM, detectors, outputs, expanders, setup in TrikdisConfig, reporting to the monitoring station, Protegus 2, SMS commands and control by phone call.

Read More
G17F fire communicator – installation and programming manual

G17F fire communicator – installation and programming manual

  • 02/11/2026

Installation and programming manual for the Trikdis G17F cellular fire communicator (EN 54-21): wiring to the outputs or to the RS485 bus of the fire alarm control panel (ESPA 4.4.4, NSC Solution, INIM Smartline, C-TEC Cast ZFP), setup in TrikdisConfig, monitoring station, Protegus 2, control by SMS and phone call.

Read More
FireCom fire communicator – installation and programming manual

FireCom fire communicator – installation and programming manual

  • 02/11/2026

Installation and programming manual for the Trikdis FireCom Ethernet and 4G fire communicator (EN 54-21, EN 54-4): power supply and battery, connection to the fire alarm control panel's outputs or RS485 bus (ESPA 4.4.4, NSC Solution, INIM Smartline, C-TEC Cast ZFP, Polon-Alfa 3000), setup in TrikdisConfig, monitoring station, Protegus 2, control by SMS and call.

Read More
🇪🇺Official EU distributiondirect from the factory
🛠️Expert supportfor installers too
✓Factory warrantyon every product
🚚Fast deliveryfrom stock