Trikdis G17F 4G GSM / IP communicator

  • €195.90 Ex Tax: €159.27



An easy and quick-to-install fire communicator that extends any fire detector unit or control panel with GSM / mobile data network event transmission.

When an input (zone) is triggered — i.e. a fire alarm is received — the event is forwarded to the configured destinations, such as the fire brigade and the monitoring station. In addition, the owner is notified via the Protegus 2 Mobile and Web application.

Key features:

  • One primary and two secondary communication channels
  • The system can be controlled from the monitoring station
  • Events are transmitted in Contact ID code format
  • Owners are notified via Protegus 2 Mobile and Web application or SMS
  • Fast and easy installation
  • Remote programming and firmware update supported
  • 3 inputs and 3 configurable contact outputs (can be used as input or output)
  • RS485 port for connecting additional devices
  • PGM outputs controlled via Protegus 2 Mobile and Web application, SMS or phone call

Related Products

Tags:

Frequently asked questions

Patrol

Patrol

4G (LTE) is faster and more future-proof, since 2G networks are being phased out. For new installations, 4G is recommended; 2G is cheaper and can be an advantage where 4G coverage is weak. Many models (FLEXi SP3, G16, CG17, G17F) are available in both versions.

Traditionally via telephone line (TIP/RING) — a universal solution that lets devices communicate regardless of brand. Trikdis's own development means that panels on the supported list (and only those) can also be connected directly and digitally via serial port or data cable — as far as we know, no one else offers this, backed by 10-15 years of development.

Protegus 2 is the 2nd generation of Trikdis's cloud app: control your alarm system from your phone and get instant notifications. We recommend it for every current internet-connected Trikdis device. The user app is free; the paid, usage- (customer-) based tier is for monitoring stations, installers and companies.

Check the product page of any direct-connection communicator — e.g. E16, G16, GT, GT+, GET: if your panel's model is on the supported list, we strongly recommend that one. In every other case, choose the telephone-line (TIP/RING) version. Pick the communication type (4G / Ethernet) based on what's available on site.

Yes, using the TrikdisConfig programming software (via USB or remotely). The latest firmware is recommended for the best compatibility and security.

With the G17F fire communicator, any fire alarm unit or panel can be extended with mobile-network event transmission: when a fire alarm triggers, the event is forwarded to the configured destinations — for example, the fire brigade or a monitoring station — and the owner is also notified in the Protegus 2 app. It handles two parallel communication channels, each with its own backup channel.

Where the fire alarm system requires standard-compliant, certified signalling, an EN54-certified device is needed: such as the Trikdis FireCom, which communicates over Ethernet and/or two-SIM 4G mobile network, and meets the strictest European fire safety requirements.

Yes: Protegus 2 can be tried on a live demo system, without installation or purchase — from a browser and from the mobile app too. This lets you see in advance what arming, notifications, and system status look like on a working alarm system.

There is no standalone Trikdis communicator that communicates exclusively over Wi-Fi, but the SIM-card communicators can be extended with the W485 Wi-Fi expansion module. There is also a purely Wi-Fi version, as well as a Wi-Fi + SIM 4G version, of the FLEXi SP3 alarm panel.

Currently the FLEXi SP3, the CG17, and the GV17 support SMS forwarding; this feature is not yet available on the other devices.

Protegus 2 typically retains the event list for up to two months; with a large volume of events, this period may shorten to as little as one month.

The AUX power output of the Paradox SP4000 alarm panel has limited load capacity. In certain cases — whether using a dedicated or a universal TRIKDIS communicator — the communicator's current draw can place too much load on the AUX output. As a result, the communicator may become unstable, restart, or fail to operate correctly.

Experience shows that the problem is usually solved by powering the TRIKDIS communicator directly from the alarm panel's battery terminals (+/-) instead of from the AUX output. This provides a stable power supply and eliminates the restart or operational issues.

Note: Before changing the wiring, always check that the system complies with the manufacturer's specifications and that the total load on the power supply does not exceed the permitted value.