Trikdis G16 2G GSM smart communicator
- Brand: Trikdis
- Product Code: G16-2G
- Availability: In Stock
- Categories: Alarm Communicator > GSM Alarm Communicator >

-
€121.90 Ex Tax: €99.11
Available Options
The video shows the installation and setup of the G16 with a Paradox Spectra control panel
The video shows how to install and configure the G16 with a DSC PowerSeries PC1864 control panel
The video shows the installation and setup of the G16 with a Honeywell Vista 20 (48) control panel
The video shows the installation and setup of the G16 with a UTC Interlogix (Caddx) NX control panel
The video shows the installation and setup of the G16 with a Crow Runner 4/8 control panel
The G16 2G GSM smart communicator can cooperate with Paradox, DSC, and other manufacturers' alarm systems directly through the data bus (DATA BUS) or serial port communication (SERIAL PORT).
Transmitting data via 2G/GPRS mobile network to the monitoring station and the user through the Protegus 2 Mobile and Web applications or SMS. With the communicator, the alarm system allows the owner to remotely arm or disarm it from the mobile app and control and monitor additional connected devices.


The Trikdis G16* and G16T communicators are excellent replacement for the Paradox PCS250(G), PCS265LEU and DSC TL405LE GSM modules.
What does Trikdis offer?
- Reliable operation
- Free Android, Iphone and web application
- * Connects directly to the control panel - this is a unique feature that nobody else is capable of
- Remote control (arming / disarming)
Alarm control panels connectable via Data Bus or Serial Port
The Trikdis E16, G16 and GET are compatible with all control panels listed below . The main advantage of these specialized Trikdis communicators is that events are transmitted via the data bus or serial port.
Control panels marked in blue can be directly controlled (arming / disarming) via the serial port or data bus, without additional wiring.
Control panels marked in black receive events via the serial port or data bus , but require key switch zones and additional wiring for full control of the alarm system .

Magellan MG5000, MG5050, MG5050+*, MG5050E
DIGIPLEX EVO48, NE96, EVO96, EVO192*, EVOHD* (*Fw. above 7.50)
ESPRIT E55, 728ULT, 738ULT
For direct control, the firmware of PARADOX alarm panels must be at least version V.4.
* The Serial Port on the designated NEW alarm panels is factory locked. The port must be enabled before it can communicate with any external device. How to unlock Serial Port


TIP-RING


Premier Elite 12, 24, 48, 64, 88, 168


You don't see your model listed above?
For not supported and other manufacturers control panels, use the G16T communicator with telephone line (TIP RING) connection.
Main features:
- GSM or 2G mobile network-based IP communicator compatible with popular alarm panels from major manufacturers
- Uniquely connects not to TIP RING but to the data bus or, in some types, the serial port, enabling message reading and transmission in less than a second
- Free Protegus 2 server, so no Fixed IP or Dynamic DNS is required
User features:
- The owner is notified of the alarm system's events through the free Protegus 2 Mobile and Web applications
- "Push" messages and distinctive sounds for event and alarm notifications
- Remote arming and disarming
Controllable outputs:
- 3 flexibly selectable contacts that can be used as inputs or outputs
- RS485 port for other compatible expansion modules and devices (available only in the 4G modem version from October 2021)
- Outputs can be controlled from the Protegus 2 application
- Control of connected devices (lighting, gates, ventilation systems, heating, sprinklers, etc.)
Quick installation:
- Settings can be saved to a file for use on another device
- Quick and easy configuration via USB or, after the initial setup, remotely using TrikdisConfig configuration software or the Protegus 2 application
- 2 access levels for configuring and managing the communicator: Administrator, Installer
Monitoring station connection:
- The module transmits messages to the monitoring station via IP in Contact ID code format for designated systems
- Compatible with universal SIA DC-09 and SUR-GUARD TL150 receivers
- In case of loss of connection to the primary monitoring channel, automatic switch to the secondary security channel
- Notification to up to two separate monitoring receivers. Both receivers have a backup security channel
You'll Need a Cable for Connection
Connection to Data Bus or Serial Port, What Does This Mean?
In this case, the communicator is practically taught to understand the alarm panel's own language (one-way communication). Just like operators or other peripheral devices, the communicator sees events and will transmit the appropriate information according to the settings.
Direct Control
In the case of directly controllable panels, the communicator not only receives notifications from the panel but also a part of the functions available on the keypad becomes accessible (bidirectional communication).
- Activation / deactivation of the entire system or partition using a user code
- Detection of zone statuses
- Zone bypass
- Automatic mapping of partitions and zones
Communication
To Protegus cloud, to iOS/Android Protegus mobile apps
To 8 mobile phones via SMS messages
Calls 8 mobile phones
WiFi, LAN, SigFox (with optional W485 / E485 / SF485 module)
SMS or voice call
Compatible devices
W485 WiFi module
E485 Ethernet module
SF485 SigFox module